Select a calculation method, then enter the connected loads from the project plans and specifications to determine the required service size per NEC 2023 Article 220.

The Optional Method allows a simplified calculation for single  dwelling units served by a single 120/240V or 208Y/120V, 3-wire set of service or feeder conductors with an ampacity of 100A or greater (NEC 220.82(A)). It totals general and fixed loads, applies 100% to the first 10 kVA and 40% to the remainder, and then adds the larger of the heating or cooling load per NEC 220.82(C).

NEC Load Calculator (Single Family Using Optional Method)
Unit Details
Building
Note: Floor area is calculated from outside dimensions, excluding open porches and unfinished areas not adaptable for future use as a habitable room or occupiable space. NEC 2023 §220.5(C): garages are included (attached and detached). NEC 2026 §120.5(C): attached garages are included; detached garages are excluded.
Small-Appliance & Laundry Circuits
1,500 VA per circuit (NEC 220.82(B)(2)).
Kitchen, dining, pantry. Min. 2.
Min. 1.
Fixed Appliances
Nameplate VA. Enter 0 if not installed.
Other Appliances
Pool pump, well pump, spa, etc. Nameplate VA.
Cooking, Laundry & Water Heating
Nameplate VA (kW × 1000).
Do not use Table 220.55 values.
California50A, 240/208V labeled circuit for future range (2025 Energy Code).
California30A, 240/208V labeled circuit for future dryer (2025 Energy Code).
California30A, 240/208V labeled circuit for future water heater (2025 Energy Code).
Heating & Cooling
The larger of heating or cooling is used (NEC 220.82(C)).
Condensing unit or heat pump. 0 if none.
AHU/FCU fan motor only (excludes supplemental heat).
Total nameplate kW.
4 or more: 40%. Fewer: 65%.
EV Charging
Counted at 100% (no demand factor).
Use charger nameplate if installed.
California40A, 208/240V EV circuit (CALGreen 4.106.4) = 9,600 VA.
*Reference: California Electric Readiness fact sheet (PDF)